EMT Practice Test

EMT Oxygen Delivery Devices: Flow Rates and Uses

Most EMT courses teach a nasal cannula at 1 to 6 L/min for mild low oxygen levels, a nonrebreather mask at 10 to 15 L/min for patients who are breathing adequately but need high-concentration oxygen, a bag-valve mask at 15 L/min with the reservoir attached for patients who are not breathing adequately, and CPAP for alert patients in respiratory distress who can follow commands.

Treat oxygen like any other medication: give it for a reason, at a dose that matches that reason, and reassess. The flow rates and oxygen percentages below are common textbook values, and the target oxygen saturations are commonly used ranges, not universal rules. Your state protocols and medical director decide what you actually do.

Quick reference

DeviceTypical flowApproximate oxygen deliveredBest for
Nasal cannula1–6 L/minAbout 24–44%Mild hypoxia, patients who cannot tolerate a mask, fine-tuning to a target saturation
Simple face mask (if your service carries one)6–10 L/minAbout 35–60%Moderate needs; less common in EMS than a nonrebreather
Nonrebreather mask10–15 L/minUp to about 90% in textbook figuresAdequate breathing with significant hypoxia, shock, suspected carbon monoxide poisoning
Bag-valve mask15 L/min with the reservoirClose to 100% with a good seal and reservoirInadequate breathing, apnea, CPR
CPAPSet by the device; pressure is commonly 5–10 cm H2OVaries by deviceAlert patients in moderate to severe respiratory distress, such as suspected pulmonary edema

Nasal cannula

The cannula is the low-flow workhorse. Each liter per minute adds roughly 4% to the inspired oxygen concentration, and flows above about 6 L/min mainly dry out the nose without adding much. Use it when a patient's saturation is a little below target, when a patient will not keep a mask on, or when you need to raise oxygen gradually, as with many COPD patients.

Nonrebreather mask

A nonrebreather delivers the highest concentration you can give a patient who is breathing on their own. Two details get tested:

  • Prefill the reservoir bag before placing the mask, and keep the flow high enough (typically 10 to 15 L/min; some programs teach 12 to 15) that the bag does not fully collapse when the patient breathes in.
  • It only works if the patient is breathing adequately. A patient with a very slow, very fast or shallow breathing pattern is not moving enough air for any mask to help. That patient needs ventilation.

Good uses include respiratory distress with low saturation, signs of shock, and suspected carbon monoxide poisoning. In carbon monoxide poisoning, the pulse oximeter can read normal or near normal even when the patient is badly poisoned, so high-concentration oxygen is given regardless of the reading.

Bag-valve mask

Use a bag-valve mask (BVM) when breathing is inadequate or absent, connected to oxygen at 15 L/min with the reservoir attached.

  • Rates: for an apneic patient with a pulse, ventilate an adult once every 6 seconds (10 breaths per minute) and an infant or child once every 2 to 3 seconds (20 to 30 per minute), per current AHA guidance.
  • Volume: squeeze over about 1 second, only until you see the chest rise. Overventilation inflates the stomach, raises the risk of vomiting and can reduce blood return to the heart.
  • Technique: two rescuers, one holding the mask seal with both hands and one squeezing the bag, is more effective than one. Insert an oral or nasal airway when appropriate.
  • Assisting a breathing patient: if a patient breathes too slowly or too shallowly, time your ventilations with the patient's own breaths and add breaths if the rate is too slow.

Signs that a patient needs a BVM rather than a mask include an altered mental status with poor respiratory effort, minimal chest rise, a very slow or very fast rate with shallow breaths, and cyanosis.

CPAP

Continuous positive airway pressure keeps the airways and alveoli open and can reduce the work of breathing. Where your state and agency allow EMTs to use it, the typical candidate is an alert adult in moderate to severe respiratory distress who can follow commands and is breathing on their own, most often from suspected pulmonary edema or a COPD flare. Some protocols include other conditions.

Common contraindications include:

  • Unresponsive, or unable to follow commands or protect the airway.
  • Respiratory arrest, agonal breathing or breathing too inadequate to trigger the device; use a BVM instead.
  • Low blood pressure (many protocols use a systolic pressure under 90 mmHg).
  • Suspected pneumothorax or significant chest trauma.
  • Facial trauma or anything that prevents a good mask seal.
  • Active vomiting or upper GI bleeding.

CPAP raises the pressure inside the chest, which can lower blood pressure, so recheck vital signs often. If the patient becomes less responsive or tires out, stop CPAP and ventilate with a BVM.

When not to give high-flow oxygen

The modern approach is to correct low oxygen levels, not to give high-flow oxygen to everyone. Many protocols target a saturation of about 94% or higher for most adults, with exceptions:

  • Suspected heart attack with normal saturation: current AHA guidance does not recommend routine oxygen when saturation is normal, commonly defined as 90% or higher. Give oxygen if the patient is hypoxic or short of breath.
  • Stroke: give oxygen to correct hypoxia, not routinely.
  • After return of circulation following cardiac arrest: avoid both low and excessive oxygen once you have a reliable reading; the 2025 AHA post-cardiac arrest algorithm lists a saturation target of 90 to 98% (the 2020 version said 92 to 98%), and your protocol governs.
  • COPD: never withhold oxygen from a hypoxic patient. Many protocols use a lower target, often 88 to 92%, and you should watch for decreasing alertness or breathing effort and be ready to ventilate.
  • Newly born babies: resuscitation of term newborns begins with room air under the neonatal guidelines, with oxygen added based on pulse oximetry.

Remember the limits of the pulse oximeter. Poor perfusion, cold hands, movement, nail polish and carbon monoxide can all give misleading readings, and the FDA has warned that pulse oximeters can be less accurate in people with darker skin pigmentation. Always treat the patient, not just the number.

Cylinder math

Exams like this formula for how long a cylinder will last:

Minutes remaining = (gauge pressure in psi minus 200 psi safe residual) x cylinder constant / flow rate in L/min

Common constants are 0.16 for a D cylinder, 0.28 for an E, 1.56 for an M, 2.41 for a G and 3.14 for an H or K. Example: a D cylinder at 2,000 psi running a nonrebreather at 15 L/min lasts about (2,000 minus 200) x 0.16 / 15, or roughly 19 minutes. Replace a cylinder when it reaches the 200 psi safe residual.

Safety basics: keep cylinders secured, keep oxygen away from open flames and smoking, and never use petroleum-based lubricants on regulators or valves.

To practice choosing the right device from a scenario, work through the airway practice questions.

EMT Practice Test

Practice questions and timed exams for the EMT cognitive test.

Start a free test

Questions

What flow rate should a nonrebreather mask run at?
Typically 10 to 15 L/min, high enough that the prefilled reservoir bag does not fully collapse when the patient inhales. Some programs teach 12 to 15 L/min.
What is the maximum flow for a nasal cannula?
EMT courses usually teach 1 to 6 L/min. Higher flows mostly dry out the nasal passages without adding much oxygen.
Should EMTs withhold oxygen from COPD patients?
No. Never withhold oxygen from a hypoxic patient. Many protocols use a lower saturation target for COPD, often 88 to 92%, and call for close monitoring of breathing effort and alertness.